Engine
- Detroit Diesel equipped with Zone II Pyroban gas cooling system. And shutdown system
- Acoustic enclosure to be rated for 85dBA @ 1 meter under full load.
- Fuel consumption 28 gallon/hr or 1.77ltr/min.
- Air starter by Ingersoll Rand (150 BMG) air starter motor
Certification
- ATEX Directive 94/9/EC
- DNV 2.7.1 Offshore Container
- SI 913
- SI 2306 (Power)
Cryogenic Pump
- CS&P triplex high pressure pump with 1 5/8” cold ends, driven by a Denison hydraulic motor.
- Maximum output flow: 3000 SCF per minute @ 6000 PSI.
85 SCM per minute @ 400 Bar. - Maximum operating pressure: 10000 PSI, 700 Bar.
- Discharge temperature: 70°F
- Hose connections NIT 150.
| Dimension | Nitrogen Unit |
| Width | 2.500 meter |
| Lenght | 5.890 meter |
| Height | 2.650 meter |
| Weight | 13.500 kg |